Home»Products »General AC Drive » ALPHA6000S Series Open Loop Vector Control AC Drive

ALPHA6000S Series Open Loop Vector Control AC Drive

ALPHA6000S series AC drive is a high-performance product under open loop vector control mode. Adoption of the international leading technology of current vector control and torque control allows this product to really achieve the decoupling of AC motor and control manner of DC motor. The superior control attributes of our product can fully satisfy the motion drive requirements of our customers.

Technical Characteristics

Input voltage fluctuation range is ±20%.

Built-in RS485 communication supports MODBUS-RTU protocol.

Flexible frequency mix-given function

Multiple programmable I/O terminals

Abundant fault-protection and running-monitor functions

Support a range of extention cards including I/O,communication card, and more.

Three control modes including V/F control, Non-PG vector control, and V/F separation control.

V/F Control
It features superior control performance of vector control. Also, it is insensitive to motor parameters.
Start Torque
0.5Hz/ 150% rated torque
Speed Range
1:100
Steady-State Precision
±0.5%
It can control the motor to run stably with 150% rated torque at 0.5Hz.
Non-PG Vector Control (Open Loop Vector Control)
Independent current loop control guarantees the real torque control. It supports the immediate switching between torque control mode and speed control mode.
Start Torque
0.5Hz/ 180% rated torque
Speed Range
1:200
Steady-State Precision
±0.5%
Torque Precision
±5%
Torque Response
﹤20ms
It can control the motor to run smoothly with 150% rated torque at 0.5Hz.

Superior Control Properties

0.1s acceleration-deceleration under rated torque is attainable.
No sudden change or oscillation occurs in current phase when motor rotation reverses at zero speed.
Mains voltage is under stable control. Quick and reliable brake is available at deceleration even without dynamic brake.

Trip-Free Running

Advanced current and voltage control technology allows the AC drive to run stably without trip when alternatively accelerated and decelerated in 0.1s command.
Due to strong load capacity, the AC drive can work continuously for 20s with 180% rated load, and 1min with 150% rated load.
The AC drive offers smooth operation with large torque at low frequency under vector control mode.

Unique treatment to instantaneous power-failure

Extraordinary torque tracking function

Without special hardware detection circuit or function code setup, the AC drive can recognize motor speed, rotation, and phase angle in 0~60Hz within0.2s. It also provides smooth tracking start of freely rotating motor.

Industry Applications

The open loop vector control AC drive can be used in various industries including the wire drawing machine, film winding machine, coating machine, CNC machinery, knitting machine, jacquard machine, fan, water pump, chemical fiber, textile, synchronous linkage, injection molding machine, rolling mill, paper making line, etc.

Technical Specification of ALPHA6000S

Item
Specification
Power Range
380V ±20% three phases: From 0.75 to 500kW
Rated Input Voltage and Frequency
380V three phases: 50/60Hz
Allowable Input Voltage Range
380V three phases: From 304 to 456V, Voltage unbalance rate of less than 3%, Frequency fluctuation of below ±5% 
Rated Output Voltage
From 0 to rated input voltage
Max. Overload Current
G model: 150% for one minute, 180% for 20 seconds
Control Method
V/F control, Open loop vector control
Frequency Range
From 0.00 to 650.00Hz (from S21R5GB to 3004GB)
From 0.00 to 400.00Hz (from 35R5GB/37R5PB to 3500G)
Frequency Accuracy
Digital command ± 0.01% (from -10℃ to +40℃)
Simulation command ± 0.01% (25℃ ± 10℃)
Preset Frequency Resolution
Digital command 0.01Hz
Simulation command 1/1000 of the maximum frequency
Output Frequency Resolution
0.01Hz
Preset Frequency Signal
From 0 to 10V, From 0 to 20mA
Acceleration-Deceleration Time
From 0.1 to 3600 seconds (The acceleration and deceleration time can be preset separately.)
Braking Torque
The additional braking resistance reaches up to 125%.
Voltage-Frequency Characteristics
Four kinds of fixed V/F characteristics are selectable.
Any V/F characteristic can be preset.
Protective Functions
Over-voltage, under-voltage, current limit, over-current, overload, electronic thermal relay, overheating, over-voltage stall, load short circuit, grounding, under-voltage protection, input phase loss, output phase loss, short circuit to ground, interphase short circuit, motor overload protection, etc
Ambient Temperature
From -10℃ to +40℃
Humidity
From 5 to 95% RH (No condensation)
Storage Temperature
From -40℃ to +70℃
Service Place
Indoor (without any corrosive gas)
Installation Site
The altitude is at most 1,000m. There is not any dust, corrosive gas, or direct solar radiation.
Vibration
Less than 5.9m/s2 (0.6g)
Protection Rating
IP20
Cooling Method
Natural cooling or forced air cooling

ALPHA6000S Model Selection

Voltage Classes
Model
Motor Power (kW)
Rated Output Current (A)
380V Three Phases
6000S-3R75GB
0.75
2.5
6000S-31R5GB
1.5
4
6000S-32R2GB
2.2
6
6000S-3004GB
4
9
6000S-35R5GB
5.5
13
6000S-37R5GB
7.5
17
6000S-3011GB
11
25
6000S-3015GB
15
32
6000S-3018G
18.5
37
6000S-3022G
22
45
6000S-3030G
30
60
6000S-3037G
37
75
6000S-3045G
45
90
6000S-3055G
55
110
6000S-3075G
75
152
6000S-3093G
93
176
6000S-3110G
110
210
6000S-3132G
132
253
6000S-3160G
160
304
6000S-3185G
185
342
6000S-3200G
200
380
6000S-3220G
220
426
6000S-3250G
250
480
6000S-3280G
280
520
6000S-3315G
315
600
6000S-3355G
355
680
6000S-3400G
400
750
6000S-3500G
500
900

Overall Dimension of ALPHA6000S Series Open Loop Vector Control AC Drive

Model
H
H1
W
W1
D
D1
D2
D3
d
6000S-3R75GB
180
169
115
105
150
158
85
120
4.5
6000S-31R5GB
6000S-32R2GB
6000S-3004GB
195
173
130
108
157
167
100
130
4.5

Model
H
H1
W
W1
D
D1
D2
d
6000S-35R5GB
270
255
190
175
176
186
122
7
6000S-37R5GB

Model
H
H1
W
W1
D
D1
D2
d
d 1
6000S-3011GB
373
360
235
200
176
188
125
7
12
6000S-3015GB
6000S-3018G
420
405
270
200
218
230
175
7
14
6000S-3022G
6000S-3030G
503
488
311
200
230
242
180
7
14
6000S-3037G
6000S-3045G
590
570
351
200
254
266
192
10
20
6000S-3055G
6000S-3075G
698
672
400
280
260
272
186
12
22
6000S-3093G
6000S-3110G
850
823
505
420
280
292
212
12
22
6000S-3132G

Installation Size of 380V 160-355kW Three-Phase Standard Model with Base

Model
W1
W2
W3
H1
H2
D1
D2
D3
d 1
d 2
6000S-3160G
600
200
530
1380
1360
400
280
60
3-φ 14
4-φ 14
6000S-3185G
6000S-3200G
6000S-3220G
6000S-3250G
800
300
730
1535
1515
410
288
60
3-φ 14
4-φ 14
6000S-3280G
6000S-3315G
6000S-3355G

Installation Size of 380V 160-355kW Three-Phase Standard Model with Wall Mount

Model
W1
W2
H1
H2
D1
D2
D3
d 1
6000S-3160G
600
200
1026
1360
400
245
77
6-φ 14
6000S-3185G
6000S-3200G
6000S-3220G
6000S-3250G
800
300
1180
1515
410
250
88
6-φ 14
6000S-3280G
6000S-3315G
6000S-3355G

Installation Size of 380V 400-500kW Three-Phase Standard Model

Model
W1
W2
W3
H1
D1
D2
D3
d 1
6000S-3400G
1000
700
900
1800
480
300
80
4-φ 22
6000S-3500G

Installation Size of 380V 160-500kW Three-Phase Narrow-Body Model

Model
W
W1
D
H
a
b
c
d
6000S-3160G
450
514
400
1600
400
315
30
15
6000S-3185G
6000S-3200G
6000S-3220G
6000S-3250G
450
514
400
1800
400
315
30
15
6000S-3280G
6000S-3315G
6000S-3355G
<

Model
W
D
H
a
b
c
d
6000S-3400G
800
550
2000
700
300
125
18