ALPHA6000 series medium voltage AC drive is an energy-efficient product under V/F control mode. It has 36 kinds of protection and warning functions. Our product offers supreme drive performance, stable operation, high precision, nice reliability, and automatic speed adjustment. It can fully satisfy the requirements of our users.

Technical Characteristics

Input voltage is 660V (±15%).

Input frequency ranges from 47 to 63Hz.

Output voltage ranges from zero to rated input voltage. Output frequency ranges from 0 to 400Hz.

Built-in PID function can realize PID closed-loop control conveniently.

Built-in RS485 communication supports MODBUS-RTU protocol.

Multiple parameters are used for online monitoring and on-line adjustment.

Prominent characteristics of soft start and soft stop

The speed regulation device gives rapid response to varying load.

Rated torque output at low speed

With strong overload capacity, the G model machine can continue working for 60s with 150% rated current, and 10s with 180% rated current.

The P model machine can work constantly for 60s with 120% rated current, and 1s with 150% rated current.

Applications

The medium voltage AC drive can be applied in the belt conveyors, scraper conveyors, fans, coal digging machines, water pumps, submersible pumps, water injection pumps, etc.

Technical Specifications of 新利18备用网址-新利18备用网址-18luck新利客户端下载

Item
Specification
Power Range
660V ±15% three phases: From 30 to 630kW
Rated Input Frequency
50/60Hz
Allowable Input Voltage Range
Three phases: From 561 to 759V, Voltage unbalance rate of less than 3%, Frequency fluctuation of below ±5%
Rated Output Voltage
From 0 to rated input voltage
Max. Overload Current
G model: 150% for one minute, 180% for 20 seconds
P model: 120% for one minute, 150% for one second
Control Method
V/F control
Frequency Range
From 0.00 to 400.00Hz
Frequency Accuracy
Digital command ± 0.01% (from -10℃ to +40℃)
Simulation command ± 0.01% (25℃ ± 10℃)
Preset Frequency Resolution
Digital command 0.01Hz
Simulation command 1/1000 of the maximum frequency
Output Frequency Resolution
0.01Hz
Preset Frequency Signal
From 0 to 10V, from 0 to 20mA
Acceleration-Deceleration Time
From 0.1 to 3600 seconds (The acceleration and deceleration time are set individually.)
Braking Torque
The additional braking resistance can reach 125%.
Voltage-Frequency Characteristics
Four kinds of fixed V/F characteristics are selectable.
Any V/F characteristic can be preset.
The V/F control with PG is available.
Protective Functions
Over-voltage, under-voltage, current limit, over-current, overload, electronic thermal relay, overheating, over-voltage stall, load short circuit, grounding, under-voltage protection, input phase loss, output phase loss, short circuit to ground, interphase short circuit, motor overload protection, etc
Ambient Temperature
From -10℃ to +40℃
Humidity
From 5 to 95% RH (No condensation)
Storage Temperature
From -40℃ to +70℃
Service Place
Indoor (without any corrosive gas)
Installation Site
The altitude is no more than 1,000m. There is not any dust, corrosive gas, or direct solar radiation.
Vibration
Less than 5.9m/s2 (0.6g)
Protection Rating
IP20
Cooling Method
Natural cooling or forced air cooling

Model Selection of 新利18备用网址-新利18备用网址-18luck新利客户端下载

Voltage Classes
Model
Motor Power (kW)
Rated Output Current (A)
660V Three Phases
6000-6030G/3037P
30/37
36/45
6000-6037G/3045P
37/45
45/52
6000-6045G/3055P
45/55
52/62
6000-6055G/3075P
55/75
62/86
6000-6075G/3093P
75/90
86/99
6000-6093G/3110P
90/110
99/125
6000-6110G/3132P
110/132
125/150
6000-6132G/3160P
132/160
150/175
6000-6160G/3185P
160/185
175/198
6000-6185G/3200P
185/200
198/218
6000-6200G/3220P
200/220
218/240
6000-6220G/3250P
220/250
240/270
6000-6250G/3280P
250/280
270/305
6000-6280G/3315P
280/315
305/350
6000-6315G/3355P
315/350
350/380
6000-6355G/6400P
355/400
380/430
6000-6400G/6500P
400/500
430/540
6000-6500G/6560P
500/560
540/600
6000-6560G/6630P
560/630
600/680
6000-6630G
630
680

Model
W1
W2
H1
H2
D1
D2
D3
d

350
200
590
570
254
266
208
4-φ 10
6000-6030G/3037P
6000-6037G/3045P
6000-6045G/3055P
6000-6055G/3075P
400
280
698
672
260
272
215
4-φ 12
6000-6075G/3093P
6000-6093G/3110P
6000-6110G/3132P

Model
W1
W2
W3
H1
H2
D1
D2
D3
d
6000-6132G/3160P
500
270

1160
1120
392
240
80
4-φ 14
6000-6160G/3185P
6000-6185G/3200P
6000-6200G/3220P
6000-6220G/3250P
6000-6250G/3280P
6000-6280G/3315P
800
580
290
1200
1150
410
270
80
4-φ 14
6000-6315G/3355P
6000-6355G/3400P

Model
W1
W2
W3
W4
H1
H2
D1
D2
D3
d 1
d 2
6000-6132G/3160P
500
270

424
1160
1120
392
270
60
2-φ 14
4-φ 14
6000-6160G/3185P
6000-6185G/3200P
6000-6200G/3220P
6000-6220G/3250P
6000-6250G/3280P
6000-6280G/3315P
800
580
290
733
1550
1150
410
270
60
3-φ 14
4-φ 14
6000-6315G/3355P
6000-6355G/3400P

Related Names
Energy-Saving Inverter | Frequency Transformer | MV Drives

Feedback Form
X